Application Area:EM Field Analysers (100's)Product Area:Health & Safety InstrumentationFrequency Range:3MHz-18GHzTuning:broadbandInterface:Via F/O to RS232Other:Walk-aboutEMC Item No:174Price:(Pricing depends on length of hire, distance, urgency and the size of the overall order. Please add your items to the request, and we'll email a quote back to you within 3 working hours.)
A small hand-held electric field probe measuring 1V/M - 800V/M. In the microwave portion of its bandwidth this equates to 0.027mW/sq.cm to 170mW/sq.cm. The display is an alphanumeric LCD. The device can be “walked around” and readings taken from the face pan. An orthogonal sensor on a 44cm rigid support mounted into the mainframe measures the field. Designed to measure in accordance with the European CENELEC standard for human exposure. Units are registered in Volts/metre – mW/sq.cm – A/Metre. Also sees much use as an integrated system for EN61000-4-3 under s/w control.
General specifications:
Measurment Range: 1V/M-800V/m. (In one range). Freq range: 3MHz-18GHz “E” field.
Display resolution: 0.01 V/M. Interface: Serial for result transfer.
General linearity: ±3dB from 1-2.5V/M and ± 1dB from 2.5-800V/M.
Absolute error: ±1dB centered on 27MHz & 27v/M.
Power: 2 x dry cells. Allowing typically 8hr use. Weight. 450gm.
Dimensions: (w x h x d) 96mm x 465mm x 64mm. Mountable on a ¼ UNC camera thread.
A small hand-held electric field probe measuring 1V/M - 800V/M. In the microwave portion of its bandwidth this equates to 0.027mW/sq.cm to 170mW/sq.cm. The display is an alphanumeric LCD. The device can be “walked around” and readings taken from the face pan. An orthogonal sensor on a 44cm rigid support mounted into the mainframe measures the field. Designed to measure in accordance with the European CENELEC standard for human exposure. Units are registered in Volts/metre – mW/sq.cm – A/Metre. Also sees much use as an integrated system for EN61000-4-3 under s/w control. General specifications: Measurment Range: 1V/M-800V/m. (In one range). Freq range: 3MHz-18GHz “E” field. Display resolution: 0.01 V/M. Interface: Serial for result transfer. General linearity: ±3dB from 1-2.5V/M and ± 1dB from 2.5-800V/M. Absolute error: ±1dB centered on 27MHz & 27v/M. Power: 2 x 1.2 rechargeable cells. Allowing typically 8hr use. Weight. 450gm. Dimensions: (w x h x d) 96mm x 465mm x 64mm. Mountable on a ¼ UNC camera thread.