Search:
Application Area:EM Transducers Conducted (200's)Product Area:Current Probes & ClampsFrequency Range:30MHz-1GHzTuning:noneInterface:BNCOther:EUT Cable 20mm max DEMC Item No:219
The absorbing clamp method of measurement is accepted by European EMC regulations as a standard method of measuring the interference power levels on cables connected to electronic & electrical devices from 30MHz - 1GHz. The clamp consists of a ferrite current transformer calibrated over the freq range with two groups of ferrite rings. The rings act as absorbers of energy & impedance stabilisers. The concept behind this is to isolate the DUT from external interference coming up from the mains.
Insertion loss: See graph as per handbook
Output impedance: 50 ohms nominal
Cable aperture: 20mm max. OD
Output connector: BNC
Dimensions: 620mm x 138mm x 103mm
Weight: 8.3kg