Application Area:EM Transducers Conducted (200's)Product Area:Injection Probes & Calibration JigsFrequency Range:2MHz-200MHzTuning:noneInterface:N(f)Other:Designed for BCIEMC Item No:242Price:(Pricing depends on length of hire, distance, urgency and the size of the overall order. Please add your items to the request, and we'll email a quote back to you within 3 working hours.)
Injection Probes are current probes designed to handle large currents in order to perform Bulk Current Injection Tests in accordance with E55101-4(Cenelec), IEC 801-6, Mil.Std.462D and various Aeronautical and Automotive specifications. Bulk Current Injection (BCI) methods are used to evaluate the EM susceptibility of a wide range of electronic devices. The BCI method simulates modulated CW currents developed in electrical circuitry on equipments under test.
Frequency Range: 2MHz - 200MHz
Insertion loss: 16dB@2MHz falling to 5dBs from 10MHzLoad Impedance: 50 ohms nominal
Maximum input power: 200W
Max power i/p duration: 30 minutes otherwise restrict to 100 W
Max Core temp: 80 degrees C
Input connector: N
Aperture: 43mm
Dimension: 110mm x 60mm long
Weight: 1.7kg