Search:
The request process takes you through from product ordering, contact information and sends your quote request
On confirmation you will receive an email from us. We at EMC Hire will then contact you to discuss your order within a working day.
Application Area:EM Transducers Conducted (200's)Product Area:Injection Probes & Calibration JigsFrequency Range:200MHz-400MHzTuning:noneInterface:N(f)Other:For BCI workEMC Item No:243Price:(Pricing depends on length of hire, distance, urgency and the size of the overall order. Please add your items to the request, and we'll email a quote back to you within 3 working hours.)
Injection Probes are current probes designed to handle large currents in order to perform Bulk Current Injection Tests in accordance with E55101-4(Cenelec), IEC 801-6, Mil.Std.462D and various Aeronautical and Automotive specifications. Bulk Current Injection (BCI) methods are used to evaluate the EM susceptibility of a wide range of electronic devices. The BCI method simulates modulated CW currents developed in electrical circuitry on equipments under test.
Frequency Coverage: 200MHz 400MHz
Insertion loss: 6dBs ± 1.5dB
Load Impedance: 50 ohms nominal
Max input power: 100W
Max pwr i/p duration: 15 mins
Max Core temp: 80 degrees C
Input connector: N
Aperture: 43mm
Dimensions: 110mm x 30mm long
Weight: 800gm