Injection Probes are current probes designed to handle large currents in order to perform Bulk Current Injection Tests in accordance with E55101-4(Cenelec), IEC 801-6, Mil.Std.462D and various Aeronautical and Automotive specifications. Bulk Current Injection (BCI) methods are used to evaluate the EM susceptibility of a wide range of electronic devices. The BCI method simulates modulated CW currents developed in electrical circuitry on equipments under test.
Frequency range: 1MHz - 700MHz
Probe Insertion loss: See Chart
Transfer Impedance: Flat @ 32dBΩ from 20MHz, 19dBΩ at 1MHz
Maximum input power: 50W limited
Max i/p power duration: 15 minutes
Aperture: 25mm
Dimensions: 94mm x 64mm long
Weight: 800gm
Can be used as a sensitive monitor probe with performance of the transfer Z in handbook. As an injection probe see Insertion Loss table to the right. Use calibration fixture item 251.