Application Area:EM Transducers Conducted (200's)Product Area:Emissions & ImmunityFrequency Range:30Hz - 250kHzTuning:noneInterface:4mm skts. and 1/4" studsOther:50amp max & 100WattEMC Item No:267Price:(Pricing depends on length of hire, distance, urgency and the size of the overall order. Please add your items to the request, and we'll email a quote back to you within 3 working hours.)
The audio isolation transformer was specifically designed for making conducted audio frequency susceptibility tests as required by MIL-STD-461/462 and other EMI specifications. It may also be used to measure low frequency EMI currents at lower levels than conventional current probes.
Frequency range: 30Hz-250kHz
Turns ratio: Two to one step down
Primary impedance: <5ohms
Secondary impedance: One-fourth primary impedance
Secondary inductance: 1mH nominal (unloaded)
Secondary saturation: 50A maximum (AC or DC)
Audio Power rating: 100W
Weight: 8.2kg
Dimensions: 115mm x 134mm x 159mm (plus terminals)
Package weight: 12kg
Package dimensions: 240mm x 240mm x 220mm.