A set of three magnetic field and two electric field probes for use as a diagnostic aid in solving emissions problems. The set also includes an extension handle and pre-amplifier with cable. Although the pre-amplifier only covers the range 300Hz-600MHz the probes alone can be used up to at least 1GHz. The set is typically used for locating and identifying the type of emission from PCBs, ICs, cables and shielding. A comprehensive handbook is enclosed.
Frequency Range: 300Hz-600MHz (with pre-amp)
100kHz-1GHz + (without pre-amp)
Probe type: 901 - 60mm loop
902 - 30mm loop
903 - 10mm loop
904 - 36mm ball
905 - 6mm stub tip
Pre-amplifier: Bandwidth - 300Hz-600MHz
Gain - 18dB (typical)
Noise (ref. 50ohms) - -6dB (typical)
DC supply: 6V Dry Cells
Battery life – 20hrs (typical)
Ancillaries: 4 spare cells, handbook, case
Weight: 1.7kg
Dimensions: 320mm x 250mm x 80mm