Fischer Capacitive Voltage Probe

In accordance with CISPR 32, Fischer Custom Communications, Inc.'s non-contact capacitive voltage probe (F-CVP-1) measures the common mode voltage appearing between a multi-pair balanced cable bundle and its local ground reference. In order to perform this voltage measurement, the F-CVP-1 does not require direct contact with the metallic conductors in the cable bundle, nor does it require the physical breaking of the cable bundle to complete the installation.

Please refer to the following list and click on the model to access the data sheet. We would be happy to provide you with a quote if you contact us through the contact page or by phone.

 

PRODUCT MAXIMUM MEASURABLE SIGNAL BATTERY CHARGER DYNAMIC RANGE MAXIMUM DIAMETER MINIMUM MEASURABLE SIGNAL NOMINAL GAIN FLATNESS NOMINAL PROBE GAIN OPERATING BANDWIDTH OUTPUT CONNECTOR OVERALL DIMENSIONS PROBE POWER SOURCE
F-CVP-14 10V External, powered from 120 VAC 80 dB minimum of wire/cable bundle under test: 2 cm for < 5 pF nominal loading for cable/bundle under test At 1kHz detection bandwidth) 10 dBµV (150 kHz – 30 MHz): +/- 0.2 dB, (9 kHz – 100 MHz): +/- 1.5 dB - 20 dB 9 kHz – 100 MHz Type N (female) 7.7 inches High X 5.0 inches Wide X 8.0 inches Long (19.6 cm X 12.7 cm X 20.3 cm) Internal rechargeable NiMH or NiCad, or disposable Alkaline (10 size AA)