EMC Item no.: | 578 |
Category: |
|
Test Mode: | Transient |
Test Type: | Dips, Interupts |
Manufacturer: | EMC Partner |
This is the Dips module required for use with the IMU4000 Mainframe modular test system.
This is required for testing to IEC/EN 61000-4-11 - Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
This item must be hired with the IMU4000 Mainframe, Item 572
Standard | IEC 61000-4-11 | |
EUT AC power | 0 V – 300 V, max. 16 A | |
EUT frequency with variac | 48 Hz – 60 Hz | |
Switch time into 100 Ω | 1 μs – 5 μs | |
Interruption time | 50 μs – 60 s | |
Inrush current | > 500 A peak | |
Dips internal variac | voltage 0 – 110 %, max. 5 A | |
Dips extern. variac | voltage 0 – 110 %, max. 16 A | |
EUT turn ON/OFF phase | selectable 0° – 359° | |
Variation mode | adjust, abrupt |
Variation internal variac | voltage 0 – 100 %, max. 5A | |
Variation external variac | voltage 0 – 100 %, max 16A | |
Interruption < one period | input as phase angle | |
Interruption > one period | input in ms | |
Ramps | Voltage, Sync angle, Time | |
Other accessories are available - please contact us