EMC Item no.: 106
Category:
  • Shielding Effectiveness
  • Site and Chamber Surveys
  • Analysers / Receivers / Power Meters
  • Tuneable Receivers and Analysers
Test Mode: Emissions
Test Type: Conducted, Radiated
Manufacturer: Rohde & Schwarz
Frequency: 9kHz-3GHz

Product description

A pre-compliant receiver testing to: CISPR16-1/VDE/EN/FCC/ VCCI. Mains operation. It’s classed as pre-compliant because the correct pulse weighting to CISPR16-1 is achieved only from 100Hz PRF or higher. In many EMC measurement situations this is not an issue. This receiver can be used as stand-alone or with our Item 124 laptop + s/w. There are two modes of operation, either as an EMI receiver (with pre-selector) or as a spectrum analyser. 

General specification

Frequency range R&S ESPI3 9 kHz to 3 GHz

Frequency resolution 0.01 Hz

External reference frequency 10 MHz

3 dB bandwidths 10 Hz to 3 MHz, in steps of 1/3/10

EMI bandwidths 6 dB bandwidths 200 Hz, 9 kHz, 120 kHz

pulse bandwidth 1 MHz

Video bandwidths analyser mode 1 Hz to 10 MHz, in steps of 1/3/10

FFT filters analyser mode

3 dB bandwidths 1 Hz to 30 kHz, in steps of 1/3/10

CW RF power RF attenuation 0 dB 20 dBm

RF attenuation ≥ 10 dB 30 dBm