Product description

Injection Probes are current probes designed to handle large currents in order to perform Bulk Current Injection Tests in accordance with E55101-4(Cenelec), IEC 801-6, Mil.Std.462D and various Aeronautical and Automotive specifications. Bulk Current Injection (BCI) methods are used to evaluate the EM susceptibility of a wide range of electronic devices. The BCI method simulates modulated CW currents developed in electrical circuitry on equipments under test.

General specification

Frequency Range: 200MHz - 400MHz

Insertion loss: 16dB@2MHz falling to 5dBs from 10MHz

Load Impedance: 50 ohms nominal

Maximum input power: 200W

Max power i/p duration: 30 minutesotherwise restrict to 100 W

Max Core temp: 80 degrees C

Input connector: N

Aperture: 43mm

Dimension: 110mm x 60mm long

Weight: 1.7kg