EMC Item no.: | 243 |
Category: |
|
Test Mode: | Immunity |
Test Type: | Conducted |
Manufacturer: | Chase |
Frequency: | 200MHz-400MHz |
Injection Probes are current probes designed to handle large currents in order to perform Bulk Current Injection Tests in accordance with E55101-4(Cenelec), IEC 801-6, Mil.Std.462D and various Aeronautical and Automotive specifications. Bulk Current Injection (BCI) methods are used to evaluate the EM susceptibility of a wide range of electronic devices. The BCI method simulates modulated CW currents developed in electrical circuitry on equipments under test.
Frequency Range: 200MHz - 400MHz
Insertion loss: 16dB@2MHz falling to 5dBs from 10MHz
Load Impedance: 50 ohms nominal
Maximum input power: 200W
Max power i/p duration: 30 minutesotherwise restrict to 100 W
Max Core temp: 80 degrees C
Input connector: N
Aperture: 43mm
Dimension: 110mm x 60mm long
Weight: 1.7kg