EMC Item no.: | 568 |
Category: |
|
Test Mode: | Transient |
Test Type: | Dips, Interupts |
Manufacturer: | EMC Partner |
This is the external DIPS module required for use with the IMU4000 Mainframe modular test system item 572. This is not included with this item
This tester simulates abnormalities of either mains or DC supplies, called power supply Dips, Interrupts or Variations. It fulfils all requirements of the IEC basic standards:
a. 61000-4-29 Ed. 1, DC dips and interrupts, for which you will need two of your own external DC supplies and
b. 61000-4-11 Ed. 2, AC mains dips, interrupts and variations, which uses the VAR-EXT1000 programmable variac in conjunction with the IMU4000D.
There is an option of a laptop pre-loaded with the requisite software. This is item 124.
Standard IEC 61000-4-11 latest edition
EUT AC power 0 V – 300 V, max. 16 A
EUT frequency with variac 48 Hz – 60 Hz
Switch time into 100 Ω 1 μs – 5 μs
Interruption time 50 μs – 60 s
Inrush current > 500 A peak
Dips internal variac voltage 0 – 110 %, max. 5 A
Dips extern. variac voltage 0 – 110 %, max. 16 A
EUT turn ON/OFF phase selectable, 0° – 359°
Variation mode adjust, abrupt
Variation internal variac voltage 0 – 100 %, max. 5A
Variation external variac voltage 0 – 100 %, max 16A
Interruption < one period input as phase angle
Interruption > one period input in ms
Ramps voltage, synchronisation angle, time
Standard IEC 61000-4-11 latest edition
Construction internal variac
Power input AC 20 – 250 V, 5 A, 50/60 Hz
Power output dips max. 275 V (110 %), max. 5 A continuous
Power output variations max. 250 V (100 %), max. 5 A continuous
Current capability dips 10 A for 5 sec., 16 A for 300 ms
Variation mode adjust, abrupt
Other accessories are available - please contact us