EMC Item no.: 248
Category:
  • Current Probes / Clamps / LISNs / CDNs
  • Injection Probes & Calibration Jigs
Test Mode: Immunity
Test Type: Conducted
Manufacturer: Solar
Frequency: 4MHz-1GHz

Product description

Injection Probes are current probes designed to handle large currents in order to perform Bulk Current Injection Tests in accordance with E55101-4(Cenelec), IEC 801-6, Mil.Std.462D and various Aeronautical and Automotive specifications. Bulk Current Injection (BCI) methods are used to evaluate the EM susceptibility of a wide range of electronic devices. The BCI method simulates modulated CW currents developed in electrical circuitry on equipments under test.

The probe can also be used for RF current monitoing with a transfer Z starting at -4dB @ 1MHz rising to +29dB @ 30MHz leveling off at 30dBs by 100MHz. Then falling gradually to 17dBs @ 1GHz.

General specification

Insertion loss: See graph

Load impedance: 50 ohms nominal

Max i/p power: 50W (30 minutes)

Max i/p current: 10 amperes

Input connector: N

Aperture: 32mm

Dimensions: 114mm x 76mm x 35mm

Weight: 570gm

Packaged weight: 1.5kg

Package dimensions: 350mm x 270mm x 85mm.