Own testing / Facility Overview / Test Services / Test Engineers / Prices
EMC testing Services
EMC hire offers a wide range of EMC testing capabilities for various sectors including commercial, automotive, and defence.
We provide radiated and conducted emissions testing to ensure compliance with regulatory standards and we offer electromagnetic compatibility tests such as transient immunity and ESD testing to meet industry-specific requirements.
We also provide testing for radiated susceptibility and electromagnetic interference. Our solutions are designed to reduce the risk of product failure and ensure product safety.
Our services adhere to industry standards such as CISPR 25 for automotive, Def Stan 59-411 for defence, and IEC 61000 for commercial electronics. By complying with these rigorous standards, we help our clients achieve certification and market readiness. Trust us to provide thorough and reliable testing that meets the highest industry benchmarks.
Test Capabilities
- Radiated Emissions Testing
- Conducted Emissions Testing
- Conducted Immunity Testing
- Radiated Immunity Testing
- Harmonics & Flicker Testing
- Automotive transient Testing
- Mains Dropout Testing
- Magnetic Field Testing
- Voltage Surge, Burst and Dips & Interruptions Testing
- Electrostatic Discharge Testing (ESD)
Test Type |
Item Number |
Test Standard |
Comment |
|
Commercial Tests To Meet CE / UKCA Requirements |
||||
Conducted Emissions |
CISPR 16-2-1 |
Low Voltage AC Mains DC Power Telecom / Network |
||
CISPR 32 |
||||
Radiated Emissions |
CISPR 16-2-3 |
Full System Pre-compliance measurements performed in a GTEM with correction factors available based on 3m and 10m test distances in an Open Area Test Site (OATS). Measurements can be performed from 30 MHz to 6 GHz |
||
Harmonics and Flicker |
EN 61000- 3-2/3 |
Low Voltage AC Mains |
||
Conducted Immunity |
EN61000-4-6 |
Signal Ports DC Power Ports AC Power Ports |
||
Radiated Immunity |
EN61000-4-3 |
Full System Test The GTEM is calibrated against the requirements of EN61000-4-20 ensuring measurements meet the requirements of EN61000-4-3. Measurements can be performed from 80 MHz to 6 GHz |
||
Magnetic Field Immunity |
EN61000-4-8 |
Full System |
||
ESD |
EN61000-4-2 |
Full System |
||
Transient Immunity |
EN61000-4-4 |
Signal Ports DC Power Ports AC Power Ports |
||
EN61000-4-5 |
||||
EN61000-4-11 |
AC Power Ports |
|||
EN61000-4-34 |
||||
Automotive Tests |
||||
Conducted Emissions |
CISPR 25 |
DC Power Voltage and Current Probe Method |
||
Radiated Emissions |
CISPR 25 |
Pre-compliance measurements using a GTEM with correction factors available based on 1m test distance in a Semi-Anechoic Chamber (SAC) |
||
Conducted Immunity |
ISO 11452-4 |
Sub-system tests BCI Test Method – closed loop and substitution |
||
Radiated Immunity |
ISO 11452-2 |
Sub-system tests Pre-compliance measurements using a GTEM. Measurements can be performed from 30 MHz to 18 GHz |
||
ESD |
ISO 10605 |
Sub-system tests |
||
Transient Immunity |
ISO 7637-2 |
|||
ISO 16750-2 |
||||
Defence Tests |
||||
Conducted Emissions |
Def Stan: DCE01 |
Sub-system tests Air, Land & Sea Service |
||
Def Stan: DCE02 AECTP: NCE05 |
||||
Mil Std: CE101 AECTP: NCE01 |
Surface Ship and Submarine DC, 60 Hz, 400 Hz Navy ASW Aircraft DC |
|||
Mil Std: CE102 AECTP: NCE02 |
All Applications AC & DC |
|||
Radiated Emissions |
Def Stan: DRE01 |
All Application Measurements using a GTEM. Measurements can be performed from 10 kHz to 18 GHz with correction factors available based on 1m test distance in a Semi-Anechoic Chamber (SAC) |
||
Def Stan: DRE01 |
||||
Mil Std: RE101 AECTP: NRE01 |
||||
Mil Std:RE102 AECTP: NRE02 |
||||
Conducted Immunity |
Def Stan: DCS01 |
Sub-system tests Air, Land & Sea Service
|
||
Def Stan:DCS03 AECTP: NCS02 |
||||
Def Stan: DCS06 |
Sub-system tests Land & Sea Service |
|||
Def Stan 61-5: DIT07.B |
Sub-system tests Land |
|||
Def Stan 61-5: DIT08.B |
Sub-system tests Land |
|||
Def Stan 61-5: DIT09.B |
Sub-system tests Land |
|||
Mil Std: CS101 AECTP: NCS01 |
Full System (All applications) |
|||
955
|
Def Stan:DCS02 |
Sub-system tests Air, Land & Sea Service |
||
Mil Std: CS114 AECTP: NCS07 |
Sub-system tests All applications |
|||
Radiated Immunity |
Def Stan: DRS02 |
All Application Pre-compliance / developmentusing a GTEM. Measurements can be performed from 10 kHz to 18 GHz @ 200V/m max field strength |
||
Mil Std: RS103 AECTP: NRS02 |
||||
Def Stan: DRS01 |
Sub-system tests Air, Land & Sea Service |
|||
Def Stan: DRS03 AECTP: NRS04 |
Sub-system tests Land Service |
|||