EMC Item no.: 206
Category:
  • Current Probes / Clamps / LISNs / CDNs
  • Current Probes & Clamps
Test Mode: Emissions
Test Type: Conducted
Manufacturer: Fischer
Frequency: 1MHz-400MHz

Product description

This is a signal current probe for measuring conducted emissions. Please see specifications.

 

General specification

Frequency Reponse:            1MHz - 400MHz

Transfer Impedance:           +17dB ohms above 100MHz

Output Impedance:             50 ohms nominal

Imax (primary):                  300A DC- 400Hz

Isig:                                   20A cw,

Pulse:                                50A

Aperture:                           25mm

Output connector:               N-type