EMC Item no.: | 232 |
Category: |
|
Test Mode: | Emissions |
Test Type: | Conducted |
Manufacturer: | Prodyn |
Frequency: | 25kHz-80MHz |
A current probe for conducted emission measurement.
Frequency range: 25kHz to 80MHz
Transfer impedance: 8dBΩ rising to 14dBΩ
Output Impedance: 50 Ω nominal
Imax (primary): 250A DC-400Hz
Isig: 10A continuous cw
Pulse: 100A
Aperture: 40mm
Connector: N-type