Skip to content

Fisher Line Impedance Stabilization Network (LISN)

A line impedance stabilization network (LISN) is a device used in conducted and radiated radio-frequency emission and susceptibility tests, as specified in various electromagnetic compatibility (EMC)/EMI test standards.

Fischer LISN Datasheet Overview

Product Max. Operating Voltage/Current Network Inductance Number of Lines RF Frequency Power Frequency Voltage Options
FCC-LISN-5-100-(X)-(XX)-DO-160F 100A 5uH 1, 2 .01 - 400 50 - 800Hz DC -1200V 60Hz - 800V 400Hz - 400V 800Hz - 230V
FCC-LISN-5-100-(X)-(XX)-MS461F 100A 5uH 1, 2, 4 .015 - 30 DC - 400Hz DC - 60Hz: 480V 400Hz: 130V
FCC-LISN-5-200-(X)-(XX)-DO-160F 100A 5uH 1, 2 .01 - 400 50 - 800Hz DC -1200V 60Hz - 800V 400Hz - 400V 800Hz - 230V
FCC-LISN-5-200-(X)-(XX)-MS461F 200A 5uH 1, 2, 4 .015 - 30 DC - 400Hz DC - 60Hz: 480V 400Hz: 130V
FCC-LISN-5-25-(X)-(XX)-MS461F 25A 5uH 1, 2, 4 .015 - 30 DC - 400Hz DC - 60Hz: 480V 400Hz: 130V
FCC-LISN-5-32-(X)-(XX)-MS461F 32A 5uH 1, 2, 4 .015 - 30 DC - 400Hz DC - 60Hz: 480V 400Hz: 130V
FCC-LISN-5-50-(X)-(XX)-DO-160F 50A 5uH 1, 2 .01 - 400 50 - 800Hz DC -1200V 60Hz - 800V 400Hz - 400V 800Hz - 230V
FCC-LISN-5-50-(X)-(XX)-MS461F 50A 5uH 1, 2, 4 .015 - 30 DC - 400Hz DC - 60Hz: 480V 400Hz: 130V
FCC-LISN-50-100-(X)-(XX) 100A 50uH 1, 2, 4 0.15 - 30 DC - 60Hz 240V / 480V
FCC-LISN-50-100-(X)-(XX)-MS461 100A 50uH 1, 2, 4 .01 - 10 50 - 400Hz 50Hz/60Hz - 240V 400Hz - 130V
FCC-LISN-50-16-(X)-(XX) 16A 50uH 1, 2, 4 0.15 - 100 DC - 60Hz 240V / 480V
FCC-LISN-50-200-(X)-(XX) 200A 50uH 1, 2, 4 0.15 - 30 DC - 60Hz 240V / 480V
FCC-LISN-50-200-(X)-(XX)-MS461 200A 50uH 1, 2, 4 .01 - 10 50 - 400Hz 50Hz/60Hz - 240V 400Hz - 130V
FCC-LISN-50-25-(X)-(XX) 25A 50uH 1, 2, 4 0.15 - 100 DC - 60Hz 240V / 480V
FCC-LISN-50-25-(X)-(XX)-MS461 25A 50uH 1, 2, 4 .01 - 10 50 - 400Hz 50Hz/60Hz - 240V 400Hz - 130V
FCC-LISN-50-32-(X)-(XX) 32A 50uH 1, 2, 4 0.15 - 100 DC - 60Hz 240V / 480V
FCC-LISN-50-32-(X)-(XX)-MS461 32A 50uH 1, 2, 4 .01 - 10 50 - 400Hz 50Hz/60Hz - 240V 400Hz - 130V
FCC-LISN-50-400-(X)-(XX) 400A 50uH 1 0.15 - 30 DC - 60Hz 240V / 480V
FCC-LISN-50-50-(X)-(XX) 50A 50uH 1, 2, 4 0.15 - 100 DC - 60Hz 240V / 480V
FCC-LISN-50-50-(X)-(XX)-MS461 50A 50uH 1, 2, 4 .01 - 10 50 - 400Hz 50Hz/60Hz - 240V 400Hz - 130V
FCC-LISN-50-50-25-(X)-(XX) 25A 50uH 1, 2, 4 0.15 - 30 DC - 60Hz 240V / 480V
FCC-LISN-50-500-(X)-(XX)-MS461 500A 50uH 1, 2, 4 .01 - 10 50 - 400Hz 50Hz/60Hz - 240V 400Hz - 130V
FCC-LISN-50/250-100-(X)-(XX) 100A 50/250uH 1, 2, 4 .009 - 30 DC - 60Hz 240V / 480V
FCC-LISN-50/250-16-(X)-(XX) 16A 50/250uH 1, 2, 4 .009 - 30 DC - 60Hz 240V / 480V
FCC-LISN-50/250-25-(X)-(XX) 25A 50/250uH 1, 2, 4 .009 - 30 DC - 60Hz 240V / 480V
FCC-LISN-50/250-32-(X)-(XX) 32A 50/250uH 1, 2, 4 .009 - 30 DC - 60Hz 240V / 480V
FCC-LISN-50/250-50-(X)-(XX) 50A 50/250uH 1, 2, 4 .009 - 30 DC - 60Hz 240V / 480V

Frequently Asked Questions

What is a LISN used for?

A LISN provides a defined impedance and isolates the EUT from external noise during EMC conducted emission testing.

Why is impedance stabilisation important?

It ensures repeatable and standardised test conditions across different test environments.

Can EMC Hire support LISN selection?

Yes. EMC Hire can advise on LISN configurations based on current, frequency range and applicable standards.

Speak to Our Team